NPS | Ball Long Pattern | Ball Short Pattern | Gate Solid Wedge Double Disc | Gate Solid Wedge Double Disc Conduit | Plug Short Venturi Pattern |
1/2 | 140 | 140 | 140 (1) | ||
3/4 | 152 | 152 | 152 (1) | ||
1 | 165 | 165 | 165 (1) | 159 (2) | |
1¼ | 178 | 178 | 178 (1) | ||
1½ | 190 | 190 | 190 | 190 (2) | |
2 | 216 | 216 | 216 | 216 | 216 |
2½ | 241 | 241 | 241 | 241 | 241 |
3 | 282 | 282 | 282 | 282 | 282 |
4 | 305 | 305 | 305 | 305 | 305 |
5 | 381 | 381 | |||
6 | 403 | 403 | 403 | 403 | 403 |
8 | 502 | 419 | 419 | 419 | 419 |
10 | 568 | 457 | 457 | 457 | 457 |
12 | 648 | 502 | 502 | 502 | 502 |
14 | 762 | 572 | 572 | 762 | 762 (3) |
16 | 838 | 610 | 610 | 838 | 838 (3) |
18 | 914 | 660 | 660 | 914 | 914 (3) |
20 | 991 | 711 | 711 | 991 | 991 (3) |
22 | 1092 | 1092 | 1092 (3) | ||
24 | 1143 | 813 | 787 | 1143 | 1143 (3) |
26 | 1245 | 1245 | 1245 (3) | ||
28 | 1346 | 1346 | 1346 (3) | ||
30 | 1397 | 1397 | 1397 (3) | ||
32 | 1524 | 1524 | 1524 (3) | ||
34 | 1626 | 1626 | 1626 (3) | ||
36 | 1727 | 1727 | 1727 (3) |
Other Pressure Classes
NPS | Plug Regular Pattern | Plug Round Port Full Bore | Globe Lift Check | Swing Check |
1/2 | 152 | |||
3/4 | 178 | |||
1 | 190 | 203 | 216 | |
1¼ | 216 | 229 | ||
1½ | 241 | 229 | 241 | |
2 | 282 | 267 | 267 | |
2½ | 330 | 292 | 292 | |
3 | 387 | 318 | 318 | |
4 | 457 | 356 | 356 | |
5 | 400 | 400 | ||
6 | 403 | 559 | 444 | 444 |
8 | 502 | 686 | 559 | 533 |
10 | 568 | 826 | 622 | 622 |
12 | 711 | 965 | 711 | 711 |
14 | 762 | 838 | ||
16 | 838 | 864 | ||
18 | 914 | 978 | ||
20 | 991 | 1016 | ||
22 | 1092 | 1118 | ||
24 | 1143 | 1346 | ||
26 | 1245 | 1346 | ||
28 | 1346 | 1499 | ||
30 | 1397 | 1594 | ||
32 | 1524 | |||
34 | 1626 | |||
36 | 1727 | 2083 |
Notes:
(1) Solid wedge only
(2) Short Pattern only
(3) Venturi Pattern only
General notes:
• Dimensions are in millimeters unless otherwise indicated.
• The face-to-face dimension for flanged Valves is the distance between the extreme ends which are the gasket contact surfaces.
• End-to-End dimensions apply to flanged Valves where the gasket contact surfaces are not located at the extreme ends of the Valve. The distance between the extreme ends is described as the end-to-end dimension and applies to flanged Valves like: Ring Joint, large or small female and large or small groove.
via:http://www.wermac.org/valves/dim_valves_ff_300.html